Trigger for 1999-2000 J/psi Runs


 
Trigger table for normal J/psi runs
TYPE BHABHA CHARGED 2-MU CHAR2 NEUTRAL Eneutral EBB BB2
Active? N Y N Y Y Y Y N
Level 1 Trigger TOF B-B - - - - - - - -
NTOF greater than or equal to1 - Y Y - - - - -
NTOF greater than or equal to2 Y - - Y - - - Y
RADIAL - - - - Y - - -
NVC greater than or equal to1 - Y - Y - - - -
Eradial - - - - - Y - Y
ETOF B-B  - - - - - - Y -
ETOF greater than or equal to1 - - - - - - - -
Nvc greater than or equal to2 - - - - - - - -
Level 2 Trigger NTRK greater than or equal to1 Y Y - - - - - -
NTRK greater than or equal to2 - - - Y - - - -
NTRK  greater than or equal to4 - - - - - - - -
MUON-OR - - Y - - - - -
ETRK - - - - - - - Y
ESC-Etot - - - - - Y Y -
Etot LOW - Y - - - - - -
Etot HIGH Y - - - Y - - -
3 - - - - - - - -
4 - - - - - - - -
 *A Y/N means that the trigger condition must/can't be met, a - means the condition is unrequired.